Safe access is provided by ladders stairs ramps etc.
Scaffold stair tower inspection requirements.
Prefabricated scaffold steps or stairs manufactured on or before may 28 2005 shall comply with the design manufacture and installation requirements of either the american national standard ansi a10 8 1988 scaffolding safety requirements or the ansi asse a10 8 2001 safety.
I have inside and or outside handrails.
The greater the potential danger to a worker the.
Scaffold is plumb and level and resting on stable footing and a firm foundation including base plates on supported scaffolds.
Whether subpart l or subpart x requirements apply to scaffold stair towers used for access to multistory buildings.
In particular one commenter ex.
2 368 suggested that osha insert a new paragraph 1926 451 c 5 as follows.
This is in response to your april 30 1999 fax asking for clarification of osha s policy regarding the use of scaffold stair towers for access to upper floors during construction of multistory buildings.
1926 451 a 1 and 3 training employers must train each employee who works on a scaffold on the hazards and the procedures to control the hazards.
Osha inspections are prioritized on a basis of risk assessment.
Suspension scaffold rigging must at least 6 times the intended load.
The scaffold is erected at a safe distance from power lines.
1926 454 inspections before each work shift and after any occurrence that could affect the structural integrity.
The scaffold does not block exits egress paths fire alarms and fire suppression systems.
Scaffold stair system installed at a project in bloomington in.
Consequently scaffold stairs which meet all the requirements of subpart x may be used for temporary access to upper floors while constructing multistory buildings.
A non scaffolder who has attended a scaffold inspection course eg a site manager could be deemed competent to inspect a basic scaffold structure.
The scaffold inspection report should note any defects or matters that could give rise to a risk to health and safety and any corrective actions taken even when those actions are taken promptly as.
Photo courtesy of matt mccreery according to an article dated september 22 2016 from the safety health practioner falls from height continue to be one of the biggest causes of fatalities and major injuries in the construction industry.
The scaffold stair towers are the most common and safest method of obtaining access to scaffold units and should be included within this subpart.
When scaffold stairs are used for access to locations other than scaffold platforms the provisions of 1926 subpart x apply.
Osha s inspection procedures for enforcing subpart l scaffolds used in construction 29 cfr 1926 450 454 establishes the methods for scaffold inspections.