Every meter of mat tested stamped to is 15652 06 specification with isi marking.
Rubber mat standard for electrical panel.
This standard supersedes is 5424.
These electrical insulating mats are manufactured according to the iec 61111 2009 standard set by the international electro technical commission.
We have mat as per standard of is 15652 2006.
Silent features of electrical insulating mat as per is 15652 2006 withstands voltages up to 65kv ac and 240v dc.
Electrical resistance up to 1494000 mega ohm.
Electrical rubber mats are effective protective gear for the operators as they give safety from electrical shock.
With the ability to reduce or stop electric currents electrical rubber matting or switchboard matting is a common surface for high voltage environments.
Fire retardant fire self extinguish within 5 seconds of lighting.
Notes to table s 2.
There is a updated directed code standard for rubber mats size material for different grade of voltage this code is called iec 61111 2009.
1969 specification for rubber mats for electrical purposes.
High elongation tensile strength.
As per international standards for safe workplace with electrical system and equipment the use of electrical insulating mats or rubber mats is mandatory.
2006 has superseded the rubber mat with is 5424 cold standard as per the govt.
Boddingtons electrical ltd manufacture a range of electrical insulating matting often referred to as switchboard matting rubber is known for its exceptional electrical insulating properties.
Of india gazette notification no.
Indian industry the standard is on the lines of relevant iec 61111 2002 06 matting of insulating materials for electrical purposes and sampling plans have been adapted from therein.
4 8 out of 5 stars 9.
2 conditions a b and c are as follows.
Mats are used near for safety of workmen from electrical shock high voltage panels sub station power transformer rooms lt ht labs near busbars near control panels etc.
1 minimum depth of clear working space in front of electric equipment with a nominal voltage to ground above 25 000 volts may be the same as that for 25 000 volts under conditions a b and c for installations built before april 16 1981.
Condition a exposed live parts on one side and no live or grounded parts on the other side of.
1 16 of over 1 000 results for electrical safety rubber mat rhino mats sb424 2436 corrugated rubber insulating switchboard mat 2 width x 3 length x 1 4 thickness 30000 vac astm type ii class 2 black.
Get contact details address of companies manufacturing and supplying electrical rubber mats electrical insulation rubber mats across india.